DPV Main Catalog 2023/2024

Lane divider IKARUS HOLM Perfect complement to turnstiles Compact, Modul Cross and Ikarus Holm 1000 Properties: - surface brushed - subdivided by 2 horizontal bars - 1000 mm width - 153 mm diameter anchoring dpvlink 20718 Type Article 6ISP.2SIH10 Lane divider IKARUS HOLM Height: 1000mm, length: 900mm Permanent monitoring Workstation monitor WS Aware WS Aware workstation monitor allows the permanent monitoring of two workstations. The measuring device equipped with a DSP (digital signal processor) monitors the flawless ground connection of users, tools and working surfaces. Furthermore, EMI events are registered and displayed. WS Aware monitors detect all grounding parameters of the working environment in accordance with the requirements of ANSI 6.1 and ANSI/ESDA S. 20. 20. TheWS Awareallows permanent monitoring and the logging of all detected events via a power data outlet either by a Facility Monitoring System (FMS) or a digital MODBUS interface, for the network via Ethernet network. WS Aware is designed to monitor the impedance of two low-ohmic grounding connections (e.g. for tools, soldering irons, machines) and two high-ohmic ones (e.g. table-mats) grounding connections. In addition, EMI voltages occurring on the low-ohmic grounding connections are monitored and displayed by a yellow LED when exceeding the set thresholds. The alarm threshold are adjustable. If there is an exceeding of the set thresholds, LEDs display this optionally (OK green, alarm red, EMI voltage yellow). Additionally, this can be shown by acoustic alarm; this function can be switched off. Not used inlets are deactivated via a DIP switch and displayed by dark LEDs. Two double-conductor wrist straps (operator and visitor) are monitored with by remote terminals that are connected to WS Awarevia cable and can be mounted e.g. on the table's base. Bleeder resistance and body voltage are permanently monitored. With terminals having a Big Brother function a photo sensor recognizes a person who is at the workstation and releases alarm, when there is no grounding through the remote terminal. Thus, working at the workstation without grounding is prevented. Properties: • "Big Brother" monitoring function detects users who are not correctly grounded • Extremely low voltage (25mV CA) for permanent monitoring of voltage and resistance of the twin conductor wrist straps • Monitoring of grounding parameters according to ANSI 6.1 and ANSI/ESD S20.20 • EMI monitoring of ground connections • RJ45 port for data transfer to the computer Wrist monitor 1 MOhm per wrist strap connector Ground connection: 2 x Remote Terminals (1 Operator, 1 visitor) Wrist connections: 0.025 V (25 mV) Test voltage to the body 10 MOhm default*. Body bleeder resistance alarm level: +/-2.5 V default*. Body voltage alarm level: Ground monitor 2 connections Hard ground terminal (tools, machine): 2 connections Dissipative surfaces: 10 Ohm default Alarm for hard grounding*: Systems against electrostatics Measurement and tests © DPV Elektronik-Service GmbH 2023 | www.dpv-elektronik.de 200

RkJQdWJsaXNoZXIy MjU0MA==